Product Image
Product added to your wishlist! View wishlist
Sign in to see your saved products on any device
Product removed from your wishlist! View wishlist
Sign in to see your saved products on any device
Something went wrong. Please try again later.
Product is added to compare already. Please refresh the page.
Product is not found in compare. Please refresh the page.
5 Products already added. Please delete existing selection to add this.

Share this product

Milcor-5'6" x 8'0" - Big Smoky UL/FM Vents - Aluminum - Milcor
This product ad may change over time
Share ProductShare

Milcor-5'6" x 8'0" - Big Smoky UL/FM Vents - Aluminum - Milcor

5'6" x 8'0" - Big Smoky UL/FM Vents - Aluminum Specifications: Material: U-LP:22 gauge Aluminum cover and 16 gauge Aluminum curb U-LPA:.063 Aluminum cover and .090 Aluminum curb U-LPAG:.063 Aluminum cover and 16 gauge Aluminum curb Finish: Aluminum: Mill Finish Aluminum: Mill Finish Cover: High-strength composite constr…
5'6" x 8'0" - Big Smoky UL/FM Vents - Aluminum Specifications: Material: U-LP:22 gauge Aluminum cover and 16 gauge Aluminum curb U-LPA:.063 Aluminum cover and .090 Aluminum curb U-LPAG:.063 Aluminum cover and 16 gauge Aluminum curb Finish: Aluminum: Mill Finish Aluminum: Mill Finish Cover: High-strength composite construction with exterior cover and liner bonded to a 2 core of rigid foam-type insulation Curb: 13 ½ in height with 3 ½ pre-drilled mounting flanges and counterflashing with 1 thick exterior fiberboard insulation Gasket: Polyurethane Foam Gasket adhered to the entire perimeter of curb Hinges: Steel Pintle Hinge Springs: Torsion Coil Spring operators to open against a 10 psf snow or wind load Dampeners: Hydraulic dampeners to control cover opening speed and prevent over-travel Latches: Latch designed to open automatically with parting of single 360 degree fusible link or manually with interior and exterior pull release handles without disturbing the fusible link. Designed to hold covers closed when subjected to 240 psf uplift pressure for U-LP or 225 psf uplift pressure for U-LPA or U-LPAG Hardware: All hardware is zinc plated (stainless steel hardware optional) Operation: Covers automatically spring open to approximately 90 degrees in the event of fire, being actuated by the parting of a single UL-listed 360 degree F fusible link, automatically locking in the fully opened position Certifications: UL 793 Listed UL 790 Certified FM Approved Milcor Heat & Smoke Vents Protect in the Event of Smoke & Fire: Opens instantly when UL listed fusible link is exposed to atemperature of 165 degrees to release noxious smoke and deadly gasesout of the building.
See more below
A
Access Doors And Panels
$9638.75
Visit site

Description

5'6" x 8'0" - Big Smoky UL/FM Vents - Aluminum Specifications: Material: U-LP:22 gauge Aluminum cover and 16 gauge Aluminum curb U-LPA:.063 Aluminum cover and .090 Aluminum curb U-LPAG:.063 Aluminum cover and 16 gauge Aluminum curb Finish: Aluminum: Mill Finish Aluminum: Mill Finish Cover: High-strength composite construction with exterior cover and liner bonded to a 2 core of rigid foam-type insulation Curb: 13 ½ in height with 3 ½ pre-drilled mounting flanges and counterflashing with 1 thick exterior fiberboard insulation Gasket: Polyurethane Foam Gasket adhered to the entire perimeter of curb Hinges: Steel Pintle Hinge Springs: Torsion Coil Spring operators to open against a 10 psf snow or wind load Dampeners: Hydraulic dampeners to control cover opening speed and prevent over-travel Latches: Latch designed to open automatically with parting of single 360 degree fusible link or manually with interior and exterior pull release handles without disturbing the fusible link. Designed to hold covers closed when subjected to 240 psf uplift pressure for U-LP or 225 psf uplift pressure for U-LPA or U-LPAG Hardware: All hardware is zinc plated (stainless steel hardware optional) Operation: Covers automatically spring open to approximately 90 degrees in the event of fire, being actuated by the parting of a single UL-listed 360 degree F fusible link, automatically locking in the fully opened position Certifications: UL 793 Listed UL 790 Certified FM Approved Milcor Heat & Smoke Vents Protect in the Event of Smoke & Fire: Opens instantly when UL listed fusible link is exposed to atemperature of 165 degrees to release noxious smoke and deadly gasesout of the building.